Study Purpose:
Non-invasive ventilation (NIV) in patients diagnosed with amyotrophic lateral sclerosis (ALS) is nowadays common practice to provide comfort at the end stage of the disease. As complaints vary there is the need of a non-invasive device to measure respiratory volume to objectify complaints.The ExSpiron© is a device for non-invasive monitoring of respiratory volume. The validation of this monitor in patients with ALS is the aim of this study.
The hypothesis is that the ExSpiron© delivers a valid assessment of respiratory volume in patients with ALS
Study Status:
Not yet recruiting
Disease:
Amyotrophic Lateral Sclerosis , Neuromuscular Diseases
Study Type:
Interventional
Type of Intervention:
Device
Intervention Name:
ExSprion
Placebo:
No
Phase:
N/A
Study Chair(s)/Principal Investigator(s):
N/A
Clinicaltrials.gov ID:
Neals Affiliated?
No
Coordinating Center Contact Information
Full Study Summary:
Rationale: Non-invasive ventilation (NIV) in patients diagnosed with amyotrophic lateral sclerosis (ALS) is nowadays common practice to provide comfort at the end stage of the disease. As complaints vary there is the need of a non-invasive device to measure respiratory volume to objectify complaints.
The ExSpiron© is a device for non-invasive monitoring of respiratory volume. The validation of this monitor in patients with ALS is the aim of this study.
The hypothesis is that the ExSpiron© delivers a valid assessment of respiratory volume in patients with ALS Objective: The primary objective is the validation of the ExSpiron© non-invasive monitor in patients diagnosed with ALS.
Study design: This is an intervention study The validation of the ExSpiron© in patients diagnosed with ALS is done during admission on the Respiratory Care Unit (RCU) of the University Medical Center Groningen (UMCG). At daytime, tidal volume (TV) and minute volume (MV) will be measured during spontaneous breathing with the ExSpiron© simultaneously with a pneumotachometer (gold-standard). After installation of the chest pad of the ExSpiron© and the pneumotachometer, the first measurements are in sitting position. Three complete cycles of ten breaths; normal breathing, slow-deep breathing and rapid-shallow breathing, will be done. Between each cycle, a pause is allowed. After completing this breathing sequence, it is repeated in supine position. If patients are not able to perform this in supine position, because of orthopnea, an angle of 45º degree is adequate. After completing this cycle, the chest pad should be left in place and the electromyography (EMG) equipment should be installed. During the first night of admission, a full night of measurement of TV and MV will be conducted using the ExSpiron©.
Study population: 10 patients diagnosed with ALS and an indication to start NIV, >18 years of age.
Intervention (if applicable): The ExSpiron© is a device for non-invasive monitoring of tidal volumes and minute ventilation in non-intubated patients by using a disposable chest pad.
Main study parameters/endpoints: The main endpoint is the validation of the ExSpiron© in patients diagnosed with ALS and screened positive for starting NIV.
Nature and extent of the burden and risks associated with participation, benefit and group relatedness: NIV has no known serious side effects. ALS patients differ in starting NIV is done on the RCU while patients are monitored as standard care, the ExSpiron© is not an extra risk complaints but those screened positive to start NIV are not associated with risks. The intervention product, ExSpiron© is a non-invasive monitor with a chest pad attached to the patient.
The ExSpiron© is a device for non-invasive monitoring of respiratory volume. The validation of this monitor in patients with ALS is the aim of this study.
The hypothesis is that the ExSpiron© delivers a valid assessment of respiratory volume in patients with ALS Objective: The primary objective is the validation of the ExSpiron© non-invasive monitor in patients diagnosed with ALS.
Study design: This is an intervention study The validation of the ExSpiron© in patients diagnosed with ALS is done during admission on the Respiratory Care Unit (RCU) of the University Medical Center Groningen (UMCG). At daytime, tidal volume (TV) and minute volume (MV) will be measured during spontaneous breathing with the ExSpiron© simultaneously with a pneumotachometer (gold-standard). After installation of the chest pad of the ExSpiron© and the pneumotachometer, the first measurements are in sitting position. Three complete cycles of ten breaths; normal breathing, slow-deep breathing and rapid-shallow breathing, will be done. Between each cycle, a pause is allowed. After completing this breathing sequence, it is repeated in supine position. If patients are not able to perform this in supine position, because of orthopnea, an angle of 45º degree is adequate. After completing this cycle, the chest pad should be left in place and the electromyography (EMG) equipment should be installed. During the first night of admission, a full night of measurement of TV and MV will be conducted using the ExSpiron©.
Study population: 10 patients diagnosed with ALS and an indication to start NIV, >18 years of age.
Intervention (if applicable): The ExSpiron© is a device for non-invasive monitoring of tidal volumes and minute ventilation in non-intubated patients by using a disposable chest pad.
Main study parameters/endpoints: The main endpoint is the validation of the ExSpiron© in patients diagnosed with ALS and screened positive for starting NIV.
Nature and extent of the burden and risks associated with participation, benefit and group relatedness: NIV has no known serious side effects. ALS patients differ in starting NIV is done on the RCU while patients are monitored as standard care, the ExSpiron© is not an extra risk complaints but those screened positive to start NIV are not associated with risks. The intervention product, ExSpiron© is a non-invasive monitor with a chest pad attached to the patient.
Study Sponsor:
University Medical Center Groningen
Estimated Enrollment:
10
Estimated Study Start Date:
03 / 01 / 2023
Estimated Study Completion Date:
09 / 01 / 2024
Posting Last Modified Date:
11 / 02 / 2022
Date Study Added to neals.org:
09 / 13 / 2019
Minimum Age:
18 Years
Maximum Age:
80 Years
Inclusion Criteria:In order to be eligible to participate in this study, a subject must meet all of the following criteria:
- Participants diagnosed with ALS requiring NIV
- Age > 18 of age; < 85 years of age
- An indication to start chronic NIV, hypercapnic respiratory failure (arterial carbon dioxide PaCO2 > 6.0 kilo pascal (kPa) measured during daytime) or orthopnoea due to diaphragm paralysis.
- Participants are able to provide feedback
- Participants that are willing to participate and are able to consent and sign the informed consent form.
Exclusion Criteria:
- A potential subject who meets any of the following criteria will be excluded from participation in this study:
- Clinically unstable
- Acute respiratory failure
- Participants with refractory hypotension, defined as systolic blood pressure less than 90 mmHg, despite inotropic agents
- Uncontrolled cardiac ischemia or arrhythmias
- Participants suffering from metastatic or terminal cancer
- Other comorbid disease affecting respiration (ie obstructive sleep apnea, chronic obstructive pulmonary disease)
- Participants lacking functional medical decision-making